INSTALLATION INSTRUCTIONS  
DISPENSING VALVES KEYED LOCK-OUT SWITCH KIT (P/N 569000262)  
ON  
VANTAGE POST-MIX DISPENSERS  
Read and understand these instructions thoroughly before installing this Dispensing Valves Keyed Lock-out  
Switch Kit (P/N 569000262) on the Post-Mix Dispensers. The purpose of the Keyed Lock-Out Switch is to shut  
off electrical power to the dispensing valves to prevent dispensing of product. Retain these instructions as part  
of your equipment manual.  
LOOSE-SHIPPED PARTS  
Note: Only qualified personnel should install this Kit.  
Unpack and inspect kit. Make sure items are present and in good condition.  
Table 1. Loose-Shipped Parts  
Name  
Item  
No.  
Part No.  
560003869  
560003870  
318948000  
318949000  
318569000  
569000261  
Qty  
1
1
Wiring Harness  
Template, Hole Drilling  
Lock Key  
2
1
3
1
4
Hex Nut  
1
5
Key-Lock Switch  
Installation Instructions  
1
6
1
KIT INSTALLATION  
WARNING: To avoid possible fatal electrical shock or serious injury to Installer, make sure  
Dispenser is disconneced from power source before attempting to install this kit.  
1. Disconnect electrical power from the Dispenser  
2. Remove hood from the Dispenser, then lift hood straight up off the Dispenser for access to the transformer  
on the refrigeration deck.  
3. Refer to Figure 1 for location of hole to be drilled in the Dispenser hood for installation of the KEY-LOCK  
SWITCH (item 5).  
4. Place TEMPLATE, HOLE DRILLING (item 2) in position on Dispenser hood as shown in Figure 1.  
5. Drill hole in Dispenser hood as indicated on the hole drilling template, then remove template from the hood.  
Revised: October 9, 2003  
February 9, 1999  
569000261  
EIMI Cornelius Inc; 1999–2003  
 
HOOD  
TEMPLATE  
(ITEM 2)  
KEY-LOCK SWITCH  
(ITEM 5)  
LOCK KEY  
(ITEM 3)  
HEX NUT  
(ITEM 4)  
1.50  
FIGURE 1. DISPENSER HOOD  
6. Install KEY-LOCK SWITCH (item 5) in the hood as shown in Figure 1 and secure with HEX NUT (item 4).  
7. Refering to Wiring Diagram (Figure 2) disconnect black electrical wire, with push-on terminal on its end,  
from terminal on the transformer outlet.  
8. Connect black electrical wire, disconnected from the transformer outlet terminal, to mating electrical wire  
terminal on the WIRING HARNESS (item 1).  
9. Connect other electrical wire of the wiring harness to output terminal on the transformer where the black  
electrical wire was disconnected from in step 7 preceding.  
10. Connect other two wiring harness terminals to two terminals on the Key-Lock Switch.  
11. Install hood on the Dispenser.  
12. Connect electrical power to the Dispenser, then check Dispenser for proper operation.  
13. Insert LOCK KEY (item 3) in key-lock switch, then check Dispenser for proper operation.  
MATING  
TERMINALS  
BLACK  
WHITE  
KEY-LOCK SWITCH  
(ITEM 5 )  
FIGURE 2. WIRING DIAGRAM  
569000261  
2
 

Cobra Digital Digital Camera DC360 User Manual
Compaq Personal Computer 4110D User Manual
Cortelco Telephone 2747 User Manual
Craftsman Lawn Mower 91725552 User Manual
Crosley Washer NLPWD15 User Manual
Cub Cadet Lawn Mower 1105 292 User Manual
Dacor Blower CABP3 User Manual
Everpure Water System DEV9108 46 User Manual
EVGA Computer Hardware 650I User Manual
Fisher Price Tent V6892 User Manual